· Dolphin Sutures

Haemostats and sealants: the layer between closure and bleeding

Oxidised cellulose, gelatin, collagen, fibrin and synthetic polymer sealants do different jobs that are frequently conflated. What each category actually is.

Haemostatic forceps, a haemostatic pad and an applicator on a blue sterile tray

Bleeding that will not respond to pressure, a stitch or diathermy is one of the oldest problems in surgery, and the category of devices addressing it is one of the most confusingly marketed. Products called haemostats, sealants, glues and matrices are frequently discussed as interchangeable. They are not, and the differences are mechanistic.

Passive haemostats

The largest category by volume works physically. A porous material is applied to a bleeding surface, where it provides a matrix that platelets adhere to and a scaffold on which a clot forms. It contributes structure; the patient’s own coagulation does the work.

Oxidised regenerated cellulose is the most familiar, supplied as a knitted or non-woven fabric. Gelatin sponges and collagen-based products work on the same principle with different substrates and handling. Some of these materials are also mildly acidic in use, which contributes to the effect.

The important limitation follows directly from the mechanism: a passive haemostat depends on the patient having functional coagulation. In a coagulopathic patient it has much less to work with, which is precisely the situation in which help is most wanted.

Active haemostats

The second category participates in the clotting cascade rather than only supporting it. Thrombin-containing products convert fibrinogen to fibrin directly at the application site. Combination products pair a thrombin component with a gelatin or collagen carrier, giving both a matrix and an active agent.

Because these products act biochemically, their sourcing carries its own considerations — human-derived, bovine-derived and recombinant thrombin all exist, and the sourcing question is a real part of the specification rather than a footnote.

Sealants

Sealants are a different proposition again. Their purpose is to close a surface or a leak, not primarily to stop bleeding — although the two overlap in practice.

Fibrin sealants combine fibrinogen and thrombin at the point of application, reproducing the final step of coagulation to form a fibrin clot. They are used for both haemostasis and sealing, and are the most established of the sealant group.

Synthetic polymer sealants — polyethylene glycol based and related chemistries — form a mechanical barrier by crosslinking in situ. They are used where a physical seal is what is wanted, for example over a suture line that is closed but not watertight.

Albumin-glutaraldehyde products crosslink to form a stiff, strongly adherent seal, used in specific vascular and cardiac applications.

Why the distinction matters in practice

Because the categories fail differently, and choosing on the wrong axis produces a predictable disappointment.

A passive haemostat on a coagulopathic patient underperforms because the mechanism assumes something the patient does not have. A sealant applied to a briskly bleeding surface may not adhere, because adhesion generally requires a surface that is not being actively washed. An active haemostat costs considerably more than a passive one and is being asked to do a job the cheaper product often does adequately.

None of these is a product defect. They are consequences of mechanism, and they are the reason the category rewards understanding what a product is rather than what it is called.

The regulatory line that runs through the middle

This category sits across a regulatory boundary that is worth knowing about. A porous cellulose fabric acting physically is regulated as a device. A product containing thrombin, or a fibrin sealant, contains a biologically active substance and is regulated accordingly — in the European framework, as a medicinal product or a device incorporating a medicinal substance, depending on its principal mode of action.

The practical consequences are real: different approval pathways, different evidence requirements, different labelling and often different purchasing routes within a hospital. Two products used at the same moment in the same operation may be governed by entirely different frameworks.

What to watch

Recombinant and non-animal-derived sourcing continues to advance, which addresses both supply and the concerns that come with animal-derived biologics. Powder and spray delivery formats are broadening where these products can be applied, particularly through laparoscopic ports. And there is steady work on materials that combine a haemostatic function with an antimicrobial or a barrier function, which is the same convergence visible across wound closure generally — fewer single-purpose products, more products doing two things at once.


This article summarises developments reported publicly across the medical-device trade press, conference programmes and clinical literature. It is general professional information — not clinical guidance, and not a claim about any Dolphin Sutures product. Device selection, indications and technique rest with the treating surgeon; refer to the Instructions for Use supplied with any device.

Talk to our team

Bulk pricing, OEM manufacturing and export documentation — response within one business day.